Skip to main content

Table 2 Transpulmonary thermodilution-derived hemodynamic variables and measured central venous pressure

From: Computed tomography to estimate cardiac preload and extravascular lung water. A retrospective analysis in critically ill patients

TPTD-derived GEDVI

  

GEDVI < 680 mL/m2,

n (%)

GEDVI 680 - 800 mL/m2,

n (%)

GEDVI > 800 mL/m2,

n (%)

14 (47%)

9 (30%)

7 (23%)

TPTD-derived EVLWI

  

EVLWI < 7 mL/kg,

n (%)

EVLWI = 7 - 10 mL/kg,

n (%)

EVLWI > 10 mL/kg,

n (%)

5 (17%)

11 (37%)

14 (47%)

CVP (measured)

  

CVP < or = 9 mmHg

CVP > 9 mmHg

 

5 (17%)

25 (83%)

 
  1. Distribution of transpulmonary thermodilution (TPTD)-derived values of global end-diastolic volume index (GEDVI) and extravascular lung water index (EVLWI) as well as values of measured central venous pressure (CVP) according to the used thresholds. Data are presented as absolute numbers (n) with percentages in parentheses.