From: Consistency and variability in human performance during simulate infant CPR: a reliability study
 | Mean (SD) absolute difference | ICC (95% CI) | SEM | MDC | MDC as % of mean (time point 1) |
---|---|---|---|---|---|
Rate QI (%) | 21 (20) | .52(−.07–.78) | 13.83 | 38.33 | 101% |
Depth QI (%) | 12 (9) | .81(.54–.91) | 3.38 | 9.33 | 21% |
Leaning QI (%) | 15 (13) | .77(.36–.90) | 6.30 | 17.47 | 42% |
Duty cycle QI (%) | 10 (11) | .68(.29–.85) | 6.25 | 17.33 | 96% |